BQKFR - AMOCO 1000 FLUID
- MSDS: BQKFR
- Manufacturer: AMOCO OIL COMPANY
- Product Name: AMOCO 1000 FLUID
- National Stock Number: 9150-00F026866
Product Identification
Product ID:AMOCO 1000 FLUID
MSDS Date:07/24/1989
FSC:9150
NIIN:00F026866
MSDS Number: BQKFR
Responsible Party
CHICAGO, IL 60601-6401
US
Emergency Phone: 800-447-8735
Info Phone: 312-856-3907
Preparer: G I BRESNICK
Cage: 15958
Contractor
Telephone: 800 447-8735
Cage: 15958
Ingredients
MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-REFINED HEAVY
CAS: 64741-88-4
RTECS: PY8040500
OSHA PEL 5 MG/CUM
ACGIH TLV: 5 MG/CUM
ZINC DIALKYLDITHIOPHOSPHATE, (ZDDP)
RTECS: TD5550000
ZINC
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: <2%
ACGIH TLV: 10 MG/CUM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ZINC COMPOUND
Fraction By Weight: <2%
Hazards
LD50 LC50 Mixture:ORAL LD50(RAT):> 10 G/KG
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: RELATIVELY NON-TOXIC.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN: IRRITATION ON REPEATED OR PROLONGED
CONTACT.
First Aid
First Aid:EYE: FLUSH W/PLENTY OF WATER. SKIN: WASH W/SOAP & WATER.
INHALATION: IF ADVERSE EFFECTS OCCUR, REMOVE TO UNCONTAMINATED
AREA. INGESTION: IF A LARGE AMOUNT, GET MEDICAL ATTENTION. OBTAIN
MEDICAL ATTENT ION IN ALL CASES.
Fire Fighting
Flash Point Method:COC
Flash Point:>390F
Extinguishing Media:DRY CHEMICAL, CO2, HALOGENATED AGENTS, FOAM, STEAM,
WATER FOG.
Accidental Release
Spill Release Procedures:REMOVE MECHANICALLY OR CONTAIN ON AN ABSORBENT
MATERIAL. TREAT AS AN OIL SPILL. KEEP OUT OF SEWERS & WATERWAYS.
Exposure Controls
Ventilation:ADEQUATE.
Protective Gloves:NEEDED FOR PROLONGED/REPEATED CONTACT.
Eye Protection:RECOMMENDED.
Supplemental Safety and Health
Chemical Properties
Spec Gravity:0.89
Solubility in Water:NEGLIGIBLE, <0.1
Appearance and Odor:DARK OILY LIQUID
Stability
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:INCOMPLETE BURNING CAN PRODUCE CO &/OR
CO2 AND OTHER HARMFUL PRODUCTS.
Disposal
Waste Disposal Methods:IN ACCORDANCE W/APPLICABLE FEDERAL, STATE OR
LOCAL REGULATIONS. ENCLOSED-CONTROLLED INCINERATION IS RECOMMENDED
UNLESS DIRECTED OTHERWISE BY APPLICABLE ORDINANCES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.